PJM · Generation

PJM marginal emission rates

What one more MWh would emit at up to 12,600 PJM pricing nodes — the RTO, its zones and the load buses — in pounds of CO2, SO2 and NOx per MWh, every hour. Negative where congestion makes the marginal unit a mix. Informational, as PJM says: it supports no claim of clean energy.

pjm-marginal-emissionshourly, ~20 min after the hour · 1h rows12,550 entities
PJM-RTO
1,209lb/MWh
2026-11-22 15:00 UTC
COMED
682lb/MWh
2026-11-22 15:00 UTC
DOM
1,306lb/MWh
2026-11-22 15:00 UTC
Read from the Dryos API and cached for an hour; the stream itself updates hourly, ~20 min after the hour.

What is in it

Updates
hourly, ~20 min after the hour · 1h rows
Entities
12,550 entities — PJM-RTO, COMED, DOM…
Source timezone
US Eastern — every timestamp Dryos serves is UTC
Coverage
16 November 2026 to now
Rows held
1,676,882
Primary key
iso, node, interval_start_utc

What it measures

Every value, its unit, and what the source means by it.

  • Marginal CO2lb/MWh

    Marginal carbon dioxide emission rate at the node for the hour.

    marginal_co2_lbs_mwh
  • Marginal SO2lb/MWh

    Marginal sulfur dioxide emission rate at the node for the hour.

    marginal_so2_lbs_mwh
  • Marginal NOxlb/MWh

    Marginal nitrogen oxides emission rate at the node for the hour.

    marginal_nox_lbs_mwh

Columns

Exactly what a request answers with, read from the API rather than written here.

ColumnTypeDescription
interval_start_utcrequiredtimestampStart of the interval, UTC, read from PJM's own UTC column.e.g. 2026-09-09T12:30:00Z
isorequiredstringPublishing ISO.e.g. PJM
noderequiredstringPJM pricing node, spelled as on the PJM LMP streams — the RTO, the zones, and the load buses (`ALDENE 230 KV T-10`, fixed-width spacing kept).e.g. PJM-RTO
marginal_co2_lbs_mwhrequirednumberMarginal carbon dioxide emission rate at the node for the hour, lbs/MWh: what one more MWh there would emit. Can be negative where congestion makes the marginal resource a mix of units moving in opposite directions.e.g. 1156.37
marginal_so2_lbs_mwhrequirednumberMarginal sulfur dioxide emission rate at the node for the hour, lbs/MWh: what one more MWh there would emit. Can be negative where congestion makes the marginal resource a mix of units moving in opposite directions.e.g. 0.26
marginal_nox_lbs_mwhrequirednumberMarginal nitrogen oxides emission rate at the node for the hour, lbs/MWh: what one more MWh there would emit. Can be negative where congestion makes the marginal resource a mix of units moving in opposite directions.e.g. 0.92
source_published_at_utctimestampWhen PJM published the row, UTC.
collected_at_utcrequiredtimestampWhen Dryos collected this row, UTC. Stamped by the platform, not the collector.e.g. 2026-09-09T12:35:12Z

Read it

Public, read-only, no key and no sign-up. Relative times stay relative, so a URL keeps working.

The newest rows

shell
curl "https://api.dryos.ai/v1/datasets/pjm-marginal-emissions/query?node=PJM-RTO&limit=12"

The catalogue entry — every column, its type and the source

shell
curl "https://api.dryos.ai/v1/datasets/pjm-marginal-emissions"

Full parameters — bucketing, aggregation, filters and search — are on the API reference.

Ask an agent

The same stream through the Model Context Protocol, so Claude, ChatGPT, Cursor or any MCP client can query it directly.

shell
claude mcp add --transport http dryos https://api.dryos.ai/mcp

Then ask:

What has Marginal CO2 been at PJM-RTO over the last 24 hours, and when did it peak?

Setup for every client is on the MCP server page.

Changes to this collector

A change in the collector is a change in the data. Anyone reading a step in a series is owed the day it moved under them.

  1. 2026-11-15

    First collected, from PJM Data Miner 2.

    The emissions counterpart of the nodal price, kept seven years by PJM. Reconciled against a live response on 2026-11-15.

How this stream is checked

  • Pulled straight from PJM Data Miner 2 · hourly_marginal_emissions — no reseller in between — and compared against that file before it is served.
  • Null means the source did not report it — never zero.
  • A reading lands hourly, ~20 min after the hour; the interval timestamp is the start of the interval, in UTC.
  • PJM's Eastern Prevailing Time observes daylight saving; its rows carry UTC as well. Every timestamp Dryos serves is UTC.

Related streams